Products
- Chemical Centrifugal Pump
- Chemical Process Pump
- Slurry Pump
- Self-priming Pump
- Magnetic Pump
- Chemical Channel Pump
- Fluoro-plastic Centrifugal Pump
- Plastic Centrifugal Pump
- Inline Pump
- Vacuum Pump
- Oil-free Vacuum Pump
- Roots Vacuum Pump
- Liquid Ring Vacuum Pump
- Water-ring Vacuum Pump
- Vacuum Unit Set
- Water Jet Vacuum Pump, Steam Jet Pump, Air Jet Pump
- Environmental Protection Equipment
- Falling Film Absorber
- Storage Tanks
- Vacuum Gauge Tank and Filter Tank
- Extruded Winding Tank
- Heat Exchanger
- Ion Exchange Column
- Microporous Filter
- Waste Gas Treatment Equipment
- Supporting Equipment
- Pipes and Fittings
- Valve
Service Hotline:
+86-571-64139900
E_mail:Info@xajpump.com
Current page: Home > Water Jet Vacuum Pump, Steam Jet Pump, Air Jet Pump Water Jet Vacuum Pump, Steam Jet Pump, Air Jet Pump



Steam Jet Pump
Xin’anjiang water jet vacuum pump and air jet pump are patented products developed by us and inject molded from RPP. The steam jet venturi tube is steel lined graphite. The pump can pump caustic gase...Xin’anjiang water jet vacuum pump and air jet pump are patented products developed by us and inject molded from RPP. The steam jet venturi tube is steel lined graphite. The pump can pump caustic gases within 150℃ and can be connected in series with steam jet pump for higher degree of vacuum. It has such features as strong corrosion resistance, high mechanical strength, smooth surface, simple structure, small size and fewer wear parts. With longest service life, large air displacement and high degree of vacuum among equivalent products.
Model Specification
Performance Diagram
Model |
Ultimate |
Guarantee |
Max. Air-bleed |
Model and |
Size of Unit |
|
Mpa |
mmHg |
|||||
RPP-25-20 |
0.0985 |
0.098 |
735 |
20 |
40FP(D)-18 (1.5) |
1100 × 600 × 800 mm |
RPP-32-40 |
0.0985 |
0.098 |
735 |
40 |
50FP(D)-22 (2.2) |
1100 × 700 × 800 mm |
RPP-40-60 |
0.098 |
0.097 |
728 |
60 |
50FP(D)-25 (3) |
1550 × 1000 × 1150 mm |
RPP-54-90 |
0.098 |
0.097 |
728 |
90 |
65FP(D)-28 (4) |
1750 × 1000 × 1200 mm |
RPP-54-110 |
0.0985 |
0.0975 |
732 |
110 |
80FP(D)-30 (5.5) |
1750 × 1000 × 1200 mm |
RPP-54-180 |
0.0993 |
0.098 |
735 |
180 |
80FP(D)-30 (5.5) |
1850 × 1000 × 1250 mm |
RPP-65-280 |
0.0993 |
0.098 |
735 |
280 |
80FP(D)-32 (7.5) |
1950 × 1000 × 1300 mm |
RPP-65-280A |
0.0996 |
0.099 |
740 |
280 |
80FP(D)-32 (7.5) |
1950 × 1000 × 1350 mm |
RPP-65-360 |
0.0995 |
0.098 |
735 |
360 |
100FP(D)-20 (11) |
2450 × 1200 × 1300 mm |
RPP-80-360 |
0.0995 |
0.098 |
740 |
360 |
100FP(D)-20 (11) |
2450 × 1200 × 1300 mm |
RPP-80-360A |
0.0998 |
0.099 |
740 |
360 |
100FP(D)-20 (11) |
2450 × 1200 × 1350 mm |
RPP-80-500 |
0.0995 |
0.098 |
735 |
500 |
100FP(D)-32 (15) |
2500 × 1200 × 1500 mm |
RPP-80-500A |
0.0996 |
0.099 |
740 |
500 |
100FP(D)-32 (15) |
2500 × 1200 × 1550 mm |
RPP-80-700 |
0.0996 |
0.098 |
735 |
700 |
100FP(D)-50 (30) |
2500 × 1800 × 1350 mm |
Stram Jet Pump |
0.1 |
0.0996 |
748 |
Steam-water series connection work with 180, 280, 360, 500; |
Note:
① The actual vacuum degree is the guarantee vacuum degree based on the local pressure × the technical paramater.
② The performances in the table refers to air temperature at 20 ℃, atmospheric pressure at 1013.25hpa (760 mmHg), relative humidity of air at 70% and temperature of circulating water at 15℃.
③ Tolerance of air pumping rate at ± 10%.
④ The readings of the degree of vacuum in the table refer to the pressure below standard atmospheric pressure. (1 mmHg = 1 Torr = 133.3 Pa, 0.1 Mpa = 750 mmHg)